2026-11-25
DELLOK completed a retubing upgrade project for a chemical plant chloride service heat exchanger. The original carbon steel tubes suffered pitting leakage; the client upgraded to SA213 TP316L stainless steel tubes during retubing to extend service life. Our service includes tube pulling, tubesheet hole inspection, defect repair, new stainless tube installation, GTAW tube-to-tubesheet welding and helium leak testing. We adjust welding procedure to avoid sensitization and intergranular corrosion at weld joints.
Why Choose Our Retubing Upgrade| Item | Specification |
|---|---|
| Tube Material | ASME SA213 TP316L |
| Service Scope | Tube removal, hole repair, new tube welding, helium leak test |
| Joint Type | Full penetration GTAW welded |
| Standard | TEMA Class R, ASME VIII Div.1 |
| Test | Hydrostatic, helium leak, PT, PMI |
| Lead Time | 30–40 days |
Chloride-containing chemical heat exchanger, wastewater heat exchanger, brine cooler.
Service ArrangementWe can perform full inspection on your existing tubesheet and advise whether hole repair or clad overlay is needed before retubing.
About Our CapabilityDELLOK handles corrosion upgrade retubing projects with stainless steel, duplex and nickel alloy tubes for chemical and fine chemical factories. Send leakage photos and original datasheet for assessment and quotation.
![]()
Send your inquiry directly to us