Home > Products > Fin Tube >
Knurled L Fin KL Finned Tube Aluminum Integral Fins Oil Gas Petrochemical

Knurled L Fin KL Finned Tube Aluminum Integral Fins Oil Gas Petrochemical

Knurled L Fin KL Finned Tube

Aluminum Fin Finned Heat Exchanger Tube

Integral Fins KL Finned Tube

Place of Origin:

Jiang Su

Brand Name:

DELLOK YONGHUI

Certification:

CE/TEMA/ASME

Model Number:

Tube Bundle

Chat Now
Request A Quote
Product Details
Base Tube OD:
15.88 Mm ~ 50.8 Mm
Base Tube Thickness:
1.0 Mm ~ 3.0 Mm
Fin Height:
6.35 Mm ~ 25.4 Mm
Fin Thickness:
0.3 Mm ~ 0.5 Mm
Fin Pitch:
2.1 Mm ~ 6.0 Mm
Tube Length:
≤ 18 Mtrs
Highlight:

Knurled L Fin KL Finned Tube

,

Aluminum Fin Finned Heat Exchanger Tube

,

Integral Fins KL Finned Tube

Payment & Shipping Terms
Minimum Order Quantity
1 Set
Price
NEGOCIATED
Packaging Details
Ply-Wooden Case /Iron Case/ Bundle with Plastic Cap
Delivery Time
30 - 90 Work Days
Payment Terms
L/C D/A D/P T/T
Supply Ability
According to Clients' Requirement
Product Description
DELLOK Knurled L Fin KL Finned Tube with Aluminum Integral Fins for Finned Heat Exchanger Tube Applications
What Is a KL Finned Tube?

A KL finned tube is a type of heat exchanger tube with fins attached to its surface. The fins increase the tube's surface area, enabling greater heat transfer between the tube and the surrounding fluid. Named after its inventor, Karl Lueger, the KL finned tube is commonly used in industrial applications where efficient heat transfer is required.

The fins on a KL finned tube are typically made of aluminum or copper and can be attached to the tube using methods such as welding, soldering, or mechanical bonding. Fins can be formed in different shapes — helical, rectangular, or oval — to optimize heat transfer for the specific application.

KL finned tubes are widely used in industries such as oil and gas, petrochemical, and power generation, where heat transfer is critical for efficient operation. They are also used in air-cooled heat exchangers, where the fins increase the surface area of the tubes exposed to air, allowing efficient cooling of the fluid flowing through the tubes.

Typical KL Finned Tube Specifications
Base Tube O.D (mm) Base Tube Thickness (mm) Fin Height (mm) Fin Thickness (mm) Fin Pitch (mm)
15.88 mm – 50.8 mm 1.0 mm – 3.0 mm 6.35 mm – 25.4 mm 0.3 mm – 0.5 mm 2.1 mm – 6.0 mm
Base Tube Material Fin Material Tube Length (Mtr)
Carbon Steel, Alloy Steel, Stainless Steel, Copper Alloy Aluminum, Copper ≤ 18 Mtrs
Additional Details About KL Finned Tubes
  • The fins on KL finned tubes are often referred to as "integral" fins because they are created by deforming the metal of the tube itself, rather than being a separate piece attached to the tube.
  • KL finned tubes can be made using a variety of tube materials such as carbon steel, stainless steel, and copper alloys, depending on the application.
  • Heat transfer performance can be affected by factors such as the shape and size of the fins, the spacing between the fins, and the fluid flow rate and temperature.
  • KL finned tubes can be designed for both liquid-to-liquid and gas-to-liquid heat transfer applications.
  • In addition to increasing heat transfer efficiency, KL finned tubes can help reduce the size and weight of heat exchangers, making them more compact and easier to transport and install.
  • KL finned tubes are often used in combination with other types of heat transfer surfaces — such as plain tubes or extended surfaces (dimpled or corrugated tubes) — to create more complex heat exchanger configurations that further optimize heat transfer performance.
KL Finned Tube Heat Transfer Performance

KL finned tubes are designed to increase the heat transfer performance of a heat exchanger by increasing the surface area available for heat transfer. The fins on the tube surface increase the surface area by several times compared to a plain tube, resulting in a higher heat transfer coefficient.

Heat transfer performance depends on several factors, including the material and geometry of the fins, the tube material, the fluid properties, and the flow conditions. Performance can be quantified by the heat transfer coefficient, which measures the rate of heat transfer per unit area of the heat transfer surface.

In general, KL finned tubes can achieve higher heat transfer coefficients compared to plain tubes, especially when the fluid on the outside of the tube is a gas. This is because the fins increase the heat transfer area and provide additional turbulence to the fluid, enhancing convective heat transfer.

However, heat transfer performance can also be affected by factors such as fouling (deposits on the heat transfer surface), corrosion, and mechanical damage. These factors can reduce the effective surface area of the fins and decrease the overall heat transfer performance of the tube. Therefore, the design and operation of a heat exchanger using KL finned tubes must account for these factors to ensure optimal heat transfer performance and reliability over the life of the equipment.

Enquiry Information for KL Finned Tube Orders

To receive a prompt offer for KL finned tubes, please include the following details in your enquiry:

  1. Base tube material
  2. Base tube size (OD * WT * Length)
  3. Fin material
  4. Fin type
  5. Finned tube diameter or fin height
  6. Fin thickness
  7. Fins per inch, fins per meter, or fin pitch
  8. Length of plain end, bare end, or unfinned length at ends
  9. Finned tube quantity
  10. Additional fabrication, such as bending or welding the tubes into a tubeplate or assembly

Send your inquiry directly to us

Privacy Policy China Good Quality Heat Exchanger Tube Bundle Supplier. Copyright © 2026 Dellok Zhenjie Energy Saving Technology Co.,Ltd. . All Rights Reserved.