Home > Products > Heat Exchanger Tubesheet >
ASTM Heat Exchanger Baffle Copper Alloy Industrial Double Tube Sheet For Baffle Plate

ASTM Heat Exchanger Baffle Copper Alloy Industrial Double Tube Sheet For Baffle Plate

ASTM heat exchanger baffle

heat exchanger baffle Copper Alloy

Baffle Plate double tube sheet

Place of Origin:

Jiang Su

Brand Name:

DELLOK YONGHUI

Certification:

CE/TEMA/ASME

Model Number:

Tube Bundle

Chat Now
Request A Quote
Product Details
Material:
Copper Alloy Steel
Design:
Customized
Components:
Tubesheet, Shell & Tube, Baffle Plate
Size:
Standard
Installation:
Easy
Thermal Conductivity:
High
Highlight:

ASTM heat exchanger baffle

,

heat exchanger baffle Copper Alloy

,

Baffle Plate double tube sheet

Payment & Shipping Terms
Minimum Order Quantity
1 Set
Price
NEGOCIATED
Packaging Details
Ply-Wooden Case /Iron Case/ Bundle with Plastic Cap
Delivery Time
30 - 90 Work Days
Payment Terms
L/C D/A D/P T/T
Supply Ability
According to Clients' Requirement
Product Description
DELLOK ASTM Copper Alloy Industrial Baffle And Tubesheet For Heat Exchanger Baffle Plate And Copper Alloy Tubesheet
Product Overview

ASTM copper alloy steel baffles and tubesheets are essential components used in heat exchangers and boilers. Baffles are plates or sheets placed inside the heat exchanger or boiler to direct the flow of fluids, enhancing heat transfer by creating turbulence and increasing contact between the fluid and the heat transfer surface. Tubesheets are large circular plates that support and seal the ends of the heat exchanger tubes, typically manufactured from copper alloy steel to provide the necessary strength and corrosion resistance.

Specifications
Design Customized Material for Tube Copper Alloy
Products Tubesheet, Shell & Tube, Baffle Plate Application Industrial
Size Standard Installation Easy
  • Copper Alloy Steel Baffle Plate
  • ASTM Heat Exchanger Tubesheet
  • Industrial Steel Baffle Plate
Key Advantages of Copper Alloy Steel Components

Copper alloy steel baffles and tubesheets are commonly used in heat exchangers due to their excellent thermal conductivity, corrosion resistance, and mechanical properties. These components play a crucial role in maximizing heat transfer efficiency and ensuring the long-term reliability of the heat exchanger.

Baffles are thin plates or discs installed inside the heat exchanger to direct fluid flow and enhance heat transfer between the hot and cold fluids. They create turbulence in the fluid, which increases the contact area between the fluid and the heat transfer surface, thereby improving heat transfer efficiency. Copper alloy steel baffles are preferred because they offer high thermal conductivity, allowing for efficient heat transfer across the plate.

Tubesheets are thick plates that support the heat exchanger tubes and provide a sealed barrier between the tube side and the shell side fluids. They are typically drilled with holes to accommodate the heat exchanger tubes, and the tubes are then expanded or welded to the tubesheet to create a secure and leak-free connection. Copper alloy steel tubesheets are chosen for their excellent corrosion resistance, as they can withstand the corrosive effects of various fluids, including seawater, acids, and alkalis.

The use of copper alloy steel baffles and tubesheets in heat exchangers offers several advantages:

  • High thermal conductivity ensures efficient heat transfer, allowing for better energy efficiency and reduced operating costs.
  • Corrosion resistance properties ensure the longevity of the heat exchanger, even when exposed to aggressive fluids.
  • Mechanical strength and durability make them suitable for high-pressure and high-temperature applications.
Heat Exchanger Configurations
Fixed Tubesheet Exchanger (L, M, and N Type Rear Headers)

In a fixed tubesheet exchanger, the tubesheet is welded to the shell. This results in a simple and economical construction, and the tube bores can be cleaned mechanically or chemically. However, the outside surfaces of the tubes are inaccessible except to chemical cleaning.

If large temperature differences exist between the shell and tube materials, it may be necessary to incorporate an expansion bellows in the shell to eliminate excessive stresses caused by expansion. Such bellows are often a source of weakness and failure in operation. In circumstances where the consequences of failure are particularly grave, U-tube or floating header units are normally used.

This is the cheapest of all removable bundle designs, but is generally slightly more expensive than a fixed tubesheet design at low pressures.

U-Tube Exchangers

In a U-tube exchanger, any of the front header types may be used and the rear header is normally an M-Type. The U-tubes permit unlimited thermal expansion, the tube bundle can be removed for cleaning, and small bundle-to-shell clearances can be achieved. However, since internal cleaning of the tubes by mechanical means is difficult, it is normal to use this type only where the tube side fluids are clean.

Floating Head Exchanger (P, S, T and W Type Rear Headers)

In this type of exchanger, the tubesheet at the rear header end is not welded to the shell but allowed to move or float. The tubesheet at the front header (tube side fluid inlet end) is of a larger diameter than the shell and is sealed in a similar manner to that used in the fixed tubesheet design. The tubesheet at the rear header end of the shell is of slightly smaller diameter than the shell, allowing the bundle to be pulled through the shell. The use of a floating head means that thermal expansion can be allowed for and the tube bundle can be removed for cleaning. There are several rear header types that can be used, but the S-Type rear head is the most popular. A floating head exchanger is suitable for the rigorous duties associated with high temperatures and pressures but is more expensive (typically on the order of 25% for carbon steel construction) than the equivalent fixed tubesheet exchanger.

Front Header Types
A-Type Front Header

This type of header is easy to repair and replace. It also gives access to the tubes for cleaning or repair without having to disturb the pipework. It does, however, have two seals (one between the tubesheet and header and the other between the header and the end plate). This increases the risk of leakage and the cost of the header over a B-Type front header.

B-Type Front Header

This is the cheapest type of front header. It is also more suitable than the A-Type front header for high-pressure duties because the header has only one seal. A disadvantage is that gaining access to the tubes requires disturbing the pipework in order to remove the header.

C-Type Front Header

This type of header is for high-pressure applications (>100 bar). It does allow access to the tube without disturbing the pipework but is difficult to repair and replace because the tube bundle is an integral part of the header.

D-Type Front Header

This is the most expensive type of front header. It is for very high pressures (>150 bar). It does allow access to the tubes without disturbing the pipework but is difficult to repair and replace because the tube bundle is an integral part of the header.

N-Type Front Header

The advantage of this type of header is that the tubes can be accessed without disturbing the pipework, and it is cheaper than an A-Type front header. However, they are difficult to maintain and replace as the header and tubesheet are an integral part of the shell.

Y-Type Front Header

Strictly speaking, this is not a TEMA-designated type but is generally recognized. It can be used as a front or rear header and is used when the exchanger is to be used in a pipeline. It is cheaper than other types of headers as it reduces piping costs. It is mainly used with single tube pass units, although with suitable partitioning any odd number of passes can be allowed.

Shell Types
E-Type Shell

This is the most commonly used shell type, suitable for most duties and applications. Other shell types tend only to be used for special duties or applications.

F-Type Shell

This is generally used when pure countercurrent flow is required in a two tube side pass unit. This is achieved by having two shell side passes—the two passes being separated by a longitudinal baffle. The main problem with this type of unit is thermal and hydraulic leakage across this longitudinal baffle unless special precautions are taken.

G-Type Shell

This is used for horizontal thermosyphon reboilers and applications where the shell side pressure drop needs to be kept small. This is achieved by splitting the shell side flow.

H-Type Shell

This is used for similar applications to the G-Type shell but tends to be used when larger units are required.

J-Type Shell

This tends to be used when the maximum allowable pressure drop is exceeded in an E-Type shell even when double segmental baffles are used. It is also used when tube vibration is a problem. The divided flow on the shell side reduces the flow velocities over the tubes and hence reduces the pressure drop and the likelihood of tube vibration. When there are two inlet nozzles and one outlet nozzle, this is sometimes referred to as an I-Type shell.

K-Type Shell

This is used only for reboilers to provide a large disengagement space in order to minimize shell side liquid carryover. Alternatively, a K-Type shell may be used as a chiller. In this case, the main process is to cool the tube side fluid by boiling a fluid on the shell side.

X-Type Shell

This is used if the maximum shell side pressure drop is exceeded by all other shell and baffle type combinations. The main applications are shell side condensers and gas coolers.

Rear Header Types
L-Type Rear Header

This type of header is for use with fixed tubesheets only, since the tubesheet is welded to the shell and access to the outside of the tubes is not possible. The main advantages of this type of header are that access can be gained to the inside of the tubes without having to remove any pipework, and the bundle-to-shell clearances are small. The main disadvantage is that a bellows or an expansion roll is required to allow for large thermal expansions, and this limits the permitted operating temperature and pressure.

M-Type Rear Header

This type of header is similar to the L-Type rear header but is slightly cheaper. However, the header has to be removed to gain access to the inside of the tubes. Again, special measures have to be taken to cope with large thermal expansions, and this limits the permitted operating temperature and pressure.

N-Type Rear Header

The advantage of this type of header is that the tubes can be accessed without disturbing the pipework. However, they are difficult to maintain and replace since the header and tubesheet are an integral part of the shell.

P-Type Rear Header

This is an outside packed floating rear header. It is, in theory, a low-cost floating head design which allows access to the inside of the tubes for cleaning and also allows the bundle to be removed for cleaning. The main problems with this type of header are:

  • Large bundle-to-shell clearances are required in order to pull the bundle.
  • It is limited to low-pressure nonhazardous fluids, because it is possible for the shell side fluid to leak via the packing rings.
  • Only small thermal expansions are permitted.

In practice, it is not a low-cost design, because the shell has to be rolled to small tolerances for the packing to be effective.

S-Type Rear Header

This is a floating rear header with a backing device. It is the most expensive of the floating head types but does allow the bundle to be removed and unlimited thermal expansion is possible. It also has smaller shell-to-bundle clearances than the other floating head types. However, it is difficult to dismantle for bundle pulling, and the shell diameter and bundle-to-shell clearances are larger than for fixed head type exchangers.

T-Type Rear Header

This is a pull-through floating head. It is cheaper and easier to remove the bundle than with the S-Type rear header, but still allows for unlimited thermal expansion. It does, however, have the largest bundle-to-shell clearance of all the floating head types and is more expensive than fixed header and U-tube types.

U-Tube

This is the cheapest of all removable bundle designs, but is generally slightly more expensive than a fixed tubesheet design at low pressures. However, it permits unlimited thermal expansion, allows the bundle to be removed to clean the outside of the tubes, has the tightest bundle-to-shell clearances, and is the simplest design. A disadvantage of the U-tube design is that it cannot normally have pure counterflow unless an F-Type shell is used. Also, U-tube designs are limited to even numbers of tube passes.

W-Type Rear Header

This is a packed floating tubesheet with a lantern ring. It is the cheapest of the floating head designs, allows for unlimited thermal expansion, and allows the tube bundle to be removed for cleaning. The main problems with this type of head are:

  • The large bundle-to-shell clearances required to pull the bundle.
  • The limitation to low-pressure nonhazardous fluids (because it is possible for both fluids to leak via the packing rings).

It is also possible for the shell and tube side fluids to become mixed if leakage occurs.

Specific Applications
  1. Heat exchangers
  2. Boilers
  3. Petrochemical industry
  4. Power generation
  5. Refrigeration and air conditioning
Product Gallery
Copper alloy steel baffle and tubesheet assembly for heat exchanger
Industrial heat exchanger bundle with copper alloy steel tubesheet and baffle plates

Send your inquiry directly to us

Privacy Policy China Good Quality Heat Exchanger Tube Bundle Supplier. Copyright © 2026 Dellok Zhenjie Energy Saving Technology Co.,Ltd. . All Rights Reserved.