Place of Origin:
Jiang Su
Brand Name:
DELLOK YONGHUI
Certification:
CE/TEMA/ASME
Model Number:
Tube Bundle
The flue at the tail of the boiler is typically fitted with an energy-saving device known as an air preheater. Its purpose is to improve the heat exchange performance of the equipment and to reuse energy, thereby reducing energy consumption. Air preheaters come in a variety of types — generally plate, rotary, and tubular — and can be further subdivided according to their heat transfer mode. The air preheater not only absorbs exhaust waste heat and improves boiler efficiency, but also raises the air temperature and strengthens combustion.
Taking the rotary air preheater as an example: it rotates slowly during operation. Flue gas enters the flue gas side of the air preheater and is then discharged, while the heat carried in the flue gas is absorbed by the heat sink inside the preheater. As the air preheater rotates slowly, the heat sink moves to the air side and transfers the heat to the air before it enters the boiler.
In boiler applications, the air preheater is mostly of the three-compartment type, equipped with a fire alarm system, a gap adjustment system, and a frequency conversion control system. Air preheaters are easy to use, simple to operate, and safe in operation, and they improve the heat exchange performance of the boiler system — which is why they are so commonly used in flue gas boiler systems.
The main heat transfer component of a tubular air preheater is thin-walled steel tube. Tubular air preheaters are mostly cubic in shape. The steel tubes are arranged vertically and staggered with each other, with both ends welded onto the upper and lower tube sheets. An intermediate tube sheet is fitted in the tube box. Flue gas passes through the preheater up and down inside the pipes, while air passes through the preheater horizontally, completing the heat transfer.
Tubular air preheaters are widely used in power station boilers and industrial boilers thanks to their good sealing, high heat transfer efficiency, and ease of manufacturing and processing. Their shortcomings include large volume, susceptibility to ash plugging inside the steel tubes, difficult cleaning, and easy wear and tear at the flue gas inlet.
| Layout Item | Horizontal Layout | Vertical Layout |
|---|---|---|
| Tube arrangement | Staggered arrangement / in-line arrangement | Staggered arrangement / in-line arrangement |
| Sealing of pipe and plate | Packing with heat-resistant material / welding | Welding |
| Anti-wearing | a. When gas scours the external tube, protective tiles are fitted on the smoke tubes. b. When gas scours inside the tube, wear casing pipes are installed at the gas inlet. |
|
Enamel air preheater products are classified by application as follows:
Send your inquiry directly to us