Home > Products > Fin Tube Bundle >
35 MPa Fin Fan Cooler Tube Bundle API 661 High Pressure Extruded Fin Core

35 MPa Fin Fan Cooler Tube Bundle API 661 High Pressure Extruded Fin Core

Extruded Fin Fin Fan Cooler Tube Bundle

API 661 Air-Cooled Heat Exchanger Tube Bundle

High Pressure 35 MPa Fin Tube Bundle

Chat Now
Request A Quote
Product Details
Max Temperature:
400°C
Max Pressure:
35 MPa
Fin Types:
Extruded, G-Type, L/LL/KL, HFW
Tube Material:
Carbon Steel Or Stainless Steel
Fin Material:
Aluminum, Copper, Or Galvanized Steel
Surface Area Increase:
10 To 20 Times
Highlight:

Extruded Fin Fin Fan Cooler Tube Bundle

,

API 661 Air-Cooled Heat Exchanger Tube Bundle

,

High Pressure 35 MPa Fin Tube Bundle

Payment & Shipping Terms
Product Description
DELLOK Extruded Fin Fin Fan Cooler Tube Bundle and Air-Cooled Heat Exchanger Tube Bundle with API 661 Standard for High Pressure 35 MPa Service
Product Overview

A Fin Fan Cooler Tube Bundle is the primary heat transfer component of an Air-Cooled Heat Exchanger (ACHE). It consists of a series of tubes—usually enhanced with fins to increase surface area—connected to headers that direct the flow of process fluids.

  • Power plants — turbine and generator cooling
  • Oil and gas — compressor, LNG, and pipeline station cooling
  • Petrochemical and refining — process fluid cooling and condensing
  • Chemical and metallurgy — process heat exchange
  • Data centers and industrial HVAC — dry cooling solutions
Fin Fan Cooler Tube Bundles by Datang

For air cooling installations, air coolers are the appropriate solution for transmitting thermal energy from an internal fluid to the ambient air. Datang supplies replacement bundles for chemical, refining, and steel plants.

Heat exchange takes place through the finned tubes, which can be attached, extruded, or of type G, L, KL, or LL. Tubes can be made of carbon steel or stainless steel depending on the nature of the fluid to be cooled. Fins are generally made of aluminium, but can also be made of copper or galvanized steel.

Aluminium offers the advantage of being lightweight and relatively insensitive to fouling. Galvanized steel provides a long service life. Whatever the type of headers—with caps, welded, or dismountable—Datang manufactures bundles that restore your installation to its original performance.

Common Tube and Fin Types
Fin Type Description Max Temperature
Extruded Fin is rolled out from an outer aluminum muff; provides the best corrosion protection for the base tube. ~285°C
G-Type (Embedded) Fin is mechanically locked into a shallow groove plowed into the tube surface. ~400°C
L/LL/KL-Foot Fin is wrapped around the tube with a foot that covers the surface; cost-effective and easy to manufacture. ~130°C to 250°C
HFW (High Frequency) Fins are spirally welded to the base tube; extremely rugged for heavy industrial use. High (material dependent)
Tube Bundle Components

A tube bundle is an assembly of tubes, headers, side frames, and tube supports. Usually the tube surface exposed to the air passage has extended surface in the form of fins to compensate for the low heat transfer rate of air at atmospheric pressure and at a low enough velocity for reasonable fan power consumption.

A Fin Fan Cooler Tube Bundle consists of the following components:

  • One or more bundles of heat transfer surface
  • An air-moving device, such as a fan, blower, or stack
  • Unless it is natural draft, a driver and power transmission to mechanically rotate the fan or blower
  • A plenum between the bundle or bundles and the air-moving device
  • A support structure high enough to allow air to enter beneath at a reasonable rate
  • Optional header and fan maintenance walkways with ladders to grade
  • Optional louvers for process outlet temperature control
  • Optional recirculation ducts and chambers for protection against freezing or solidification of high pour point fluids in cold weather
  • Optional variable pitch fan hub for temperature control and power savings
Advantages of Air-Cooled Heat Exchanger Tube Bundles
  • Waterless Cooling: Utilizes air for heat exchange, eliminating the need for a water source or water treatment system.
  • Expanded Heat Exchange Area: Leverages a finned structure to increase the heat exchange surface area of a single tube by 10 to 20 times.
  • Low Maintenance: Prevents scale accumulation and external biological corrosion on the tubes, thereby reducing cleaning frequency.
  • Operational Adaptability: The structural design accommodates high-pressure (35 MPa) and high-temperature (400°C) operating environments.
  • Standardized Design: Complies with standards such as API 661, facilitating modular transportation and installation.
Applications
  • Refining and Petrochemicals: Used in hydroprocessing units, atmospheric and vacuum distillation units, catalytic cracking units, and other facilities to cool crude oil, refined products, and reaction products. Examples include air-cooled tube bundles in residue hydroprocessing units.
  • Air Compressor Systems: Serve as intercoolers and aftercoolers to cool compressed air (e.g., components for compressors from brands such as Atlas Copco and Ingersoll Rand).
  • Power Industry: Used in the condensing systems of air-cooled steam turbines (both indirect and direct air-cooling configurations).
Extended Surface Fin Types Available
  • L-foot fin: Basic embedded fin, economical and widely used for general-purpose cooling.
  • Overlapped L-foot fin (LL type): Provides better corrosion resistance by overlapping the fin foot over the tube surface.
  • Embedded G-fin: Fins mechanically embedded into the tube surface for improved thermal contact and durability.
  • Knurled L-foot fin (KL type): Uses a knurled surface on the tube to enhance mechanical bonding between fin and tube.
  • Extruded fin: Formed by extruding aluminum over the tube for maximum corrosion resistance and strength, ideal for harsh environments.
  • Bimetallic finned tubes: E.g., aluminum fins on carbon steel or stainless steel tubes, combining thermal conductivity with structural or corrosion benefits.
  • Custom fin materials and geometries available upon request.
Optional Configurations
  • Compliance with ASME and API 661 standards
  • Forced Draft or Induced Draft fan arrangements
  • Horizontal or Vertical air flow design
  • Smart Controls (temperature sensors, variable speed fans)
  • Explosion-Proof, Low-Noise, or Marine-Grade Designs
  • Dry/Wet Hybrid System for enhanced performance in high ambient temperatures
  • Custom painting and corrosion protection
Header Types Available
  • Plug-type header: For compact or low-cost design.
  • Removable cover plate header: For easy inspection and maintenance.
  • Removable bonnet-type header: For higher-pressure applications with external access.
  • Manifold-type header: For multi-pass or special flow arrangements.
Air Fin Cooler Tube Bundle Water Pressure Test

An air fin cooler tube bundle water pressure test uses water as the medium. Water is injected into the equipment and pressurized to test the equipment's sealing and pressure-bearing capacity.

Pressure testing is crucial for the safe operation of air coolers. It allows for the timely identification and resolution of equipment problems, such as leaky seals and insufficient pressure-bearing capacity. Failure to identify and address these issues can lead to equipment failures and even accidents. Therefore, pressure testing is not only a test of equipment performance but also a safeguard for industrial safety.

Fin fan cooler tube bundle with finned tubes and headers during assembly
Close-up view of finned tubes on an air-cooled heat exchanger tube bundle

Send your inquiry directly to us

Privacy Policy China Good Quality Heat Exchanger Tube Bundle Supplier. Copyright © 2026 Dellok Zhenjie Energy Saving Technology Co.,Ltd. . All Rights Reserved.